ANERN AN-SCI-MAX Hybrid Solar Inverter 1kW 3kW 4.2kW 6.2kW 10.2kW Built-in MPPT 500VDC PV 230VAC 12V 24V 48V Pure Sine Wave CE RoHS
Pickup currently not available
SPECIFICATIONS
Brand Name: ANERN
Certification: CE,RoHS
EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
High-concerned chemical: None
Is Smart Device: Yes
Model Number: AN-SCI-MAX
Origin: Mainland China
Output Frequency: 50Hz/60Hz
Output Type: SINGLE
Weight: 7KG-20KG
is_customized: Yes
Features:
Connectable battery type: Lead-acid/Lithium iron phosphate(LiFePO4)/colloid/lithium battery
Model |
SCI-MAX-10200 |
RATED POWER |
10200W |
Maximum PV Input Power |
10800W |
GRID-TIED OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
MPPT DC Voltage Range |
90-450VDC |
|
Number of MPPT Trackers/Maximum
Input Current
|
2/18A |
GRID OUTPUT (AC) |
Nominal AC Output Voltage |
220/230/240VAC |
AC Output Voltage Range |
195.5-253VAC |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
Nominal Output Current |
44.3A |
EFFICIENCY |
Maximum Conversion Efficiency (Solar to AC) |
98% |
TWO LOADS OUTPUT POWER |
Full Load |
10200W |
Maximum Main Load |
10200W |
Maximum Second Load (battery mode)(Only if the battery voltage is below 44V) |
3400W |
Main Load Cut Off Voltage |
44VDC |
Main Load Return Voltage |
48VDC |
OFF-GRID OPERATION |
AC Start-up Voltage/Auto Restart Voltage |
120-140VAC/180VAC |
Acceptable Input Voltage Range |
90-280VAC or 170-280VAC |
Maximum AC Input Current |
50A |
Nominal Operating Frequency |
50/60Hz |
Surge Power |
20400W |
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
BATTERY & CHARGER |
Nominal DC Voltage |
48VDC |
Maximum Charging Current(Solar to AC) |
160A |
Maximum AC Charging Current |
160A |
GENERAL |
Communication interface |
WIFI |
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
–10°C - 50°C |
Storage Temperature |
–15°C - 60°C |


Model |
SCI-ECO-4200 |
SCI-ECO-6200 |
RATED POWER |
4200W |
6200W |
Maximum PV Input Power |
6200W |
6500W |
GRID-TIED OPERATION |
PV INPUT (DC) |
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
|
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
|
Maximum DC Voltage |
60-450VDC |
|
Number of MPPT Trackers/Maximum Input Current |
18A |
22A |
GRID OUTPUT (AC) |
Nominal AC Output Voltage |
220/230/240VAC |
AC Output Voltage Range |
195.5-253VAC |
Nominal Output Current |
18.2A |
27.0A |
Power Factor |
>0.99 |
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
EFFICIENCY |
Maximum Conversion Efficiency (Solar to AC) |
98% |
TWO LOADS OUTPUT POWER |
Full Load |
4200W |
6200W |
Maximum Main Load |
4200W |
6200W |
Maximum Second Load (battery mode) |
1400W |
2067W |
Main Load Cut Off Voltage |
22VDC |
44VDC |
Main Load Return Voltage |
26VDC |
52VDC |
OFF-GRID OPERATION |
AC Start-up Voltage/Auto Restart Voltage |
120-140VAC/180VAC |
Acceptable AC Input Voltage Range |
90-280VAC or 170-280VAC |
Maximum AC Input Current |
30A |
40A |
Nominal Operating Frequency |
50/60Hz |
Surge Power |
8400W |
12400W |
BATTERY MODE OUTPUT (AC) |
Nominal Output Voltage |
220/230/240VAC |
Output Waveform |
Pure sine wave |
Efficiency (DC to AC) |
94% |
BATTERY & CHARGER |
Nominal DC Voltage |
24VDC |
48VDC |
Maximum Charging Current(Solar to AC) |
120A |
Maximum AC Charging Current |
100A |
GENERAL |
Dimension, D x W x H (mm) |
420*350*110mm |
450*350*110mm |
Communication interface |
WIFI |
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
–10°C - 50°C |
Storage Temperature |
–15°C - 60°C |



Model |
SCI-ECO-2000 |
SCI-ECO-3200 |
RATED POWER |
2000VA/1600W |
3200VA/3000W |
AC INPUT |
AC Input Voltage |
230VAC |
Selectable Voltage Range |
170-280 VAC (For Personal Computers) |
Selectable Voltage Range |
90-280 VAC (For Home Appliances) |
Frequency Range |
50 Hz/60 Hz (Auto sensing) |
AC OUTPUT |
AC Voltage Regulation (Batt. Mode) |
230VAC ± 5% |
Surge Power |
4000VA |
6400VA |
Efficiency (Peak) PV to Inverter |
98% |
Efficiency (Peak) Battery to Inverter |
94% |
Transfer Time |
10 ms (For Personal Computers); 20 ms (For Home Appliances) |
Waveform |
Pure sine wave |
BATTERY & AC CHARGER |
Battery Voltage |
12VDC |
24VDC |
Floating Charge Voltage |
13.5VDC |
27VDC |
Overcharge Protection |
16VDC |
33VDC |
Maximum AC Charge Current |
60A |
SOLAR CHARGER |
Maximum PV Array Power |
2000W |
3000W |
MPPT Range @ Operating Voltage |
30-400VDC |
Maximum PV Array Open Circuit Voltage |
400VDC |
Maximum Charging Current |
80A |
PHYSICAL |
Dimension, D x W x H (mm) |
360*270*100mm |
390*270*100mm |
INTERFACE |
Communication interface |
WIFI |
OPERATING ENVIRONMENT |
Humidity |
5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature |
–10°C - 50°C |
Storage Temperature |
–15°C - 60°C |





Model |
SCI-ES-1000 |
RATED POWER |
1000VA/1000W |
AC INPUT |
AC Input Voltage |
230VAC |
Selectable Voltage Range |
170-280 VAC (For Personal Computers) |
Selectable Voltage Range |
90-280 VAC (For Home Appliances) |
Frequency Range |
50 Hz/60 Hz (Auto sensing) |
AC OUTPUT |
AC Voltage Regulation (Batt. Mode) |
230VAC ± 5% |
Surge Power |
2000VA |
Efficiency (Peak) PV to Inverter |
98% |
Efficiency (Peak) Battery to Inverter |
94% |
Transfer Time |
10 ms (For Personal Computers); 20 ms (For Home Appliances) |
Waveform |
Pure sine wave |
BATTERY & AC CHARGER |
Battery Voltage |
12VDC |
Floating Charge Voltage |
13.5VDC |
Overcharge Protection |
16VDC |
Maximum AC Charge Current |
40A |
SOLAR CHARGER |
Maximum PV Array Power |
600W |
MPPT Range @ Operating Voltage |
20-150VDC |
Maximum PV Array Open Circuit Voltage |
150VDC |
Maximum Solar Charging Current |
40 |
Maximum (AC+Solar)Charging Current |
80A |
PHYSICAL |
Dimension, D x W x H (mm) |
286*240*91mm |
INTERFACE |
Communication interface |
WIFI |
OPERATING ENVIRONMENT |
Humidity |
5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature |
–10°C - 50°C |
Storage Temperature |
–15°C - 60°C |







Inverter Use Notice
1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.

FAQ:
Q:Whether it can be connected to the grid?
A:PV gives priority to power supply to the load, and extra to charge the battery, and more can be integrated into the grid (need to be based on local government policies)
Q: Is it possible to use PV, battery, grid supply at the same time?
A: YES. The default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
Q: Can inverters be connected in series or parallel?
A: NO.
Q: Can the utility be used to power the inverter when there is no sun?
A: YES.
Q: How to choose the power of the inverter according to the household appliances?
A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter is at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
Q: How many solar panels need to be connected?
A: In order to start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, The maximum does not exceed 500V.