SPECIFICATIONS
Battery Type: Lifepo4 Batteries, Lithium Batterie
Brand Name: ANERN
Certification: CE,RoHS
EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
Grid Tie Inverter: MPPT Solar Inverter
High-concerned chemical: None
Hybrid Solar Inverter 48V: Grid-tie Hybrid Inverter Charger
Is Smart Device: Yes
Max Panel Input Voltage: 450V/500V
Model Number: AN-SCI-MAX
Nominal Output Voltage: 220V 230V 240V
Origin: Mainland China
Output Current: 1/27A
Output Frequency: 50Hz 60Hz
Output Power: 1 - 200 KW
Output Type: SINGLE
Size: 537*390*130mm
Weight: 15kg
is_customized: Yes
|
Model |
SCI-MAX-10200 |
|
RATED POWER |
10200W |
|
Maximum PV Input Power |
10800W |
|
GRID-TIED OPERATION |
|
PV INPUT (DC) |
|
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
|
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
|
MPPT DC Voltage Range |
90-450VDC |
|
Number of MPPT Trackers/Maximum
Input Current
|
2/18A
|
|
GRID OUTPUT (AC) |
|
Nominal AC Output Voltage |
220/230/240VAC |
|
AC Output Voltage Range |
195.5-253VAC |
|
Power Factor |
>0.99 |
|
Feed-in Grid Frequency Range |
49-51±1Hz / 59-61±1Hz |
|
Nominal Output Current
|
44.3A
|
|
EFFICIENCY |
|
Maximum Conversion Efficiency (Solar to AC) |
98% |
|
TWO LOADS OUTPUT POWER |
|
Full Load |
10200W |
|
Maximum Main Load |
10200W |
|
Maximum Second Load (battery mode)(Only if the battery voltage is below 44V) |
3400W |
|
Main Load Cut Off Voltage |
44VDC |
|
Main Load Return Voltage |
48VDC |
|
OFF-GRID OPERATION |
|
AC Start-up Voltage/Auto Restart Voltage
|
120-140VAC/180VAC
|
|
Acceptable Input Voltage Range
|
90-280VAC or 170-280VAC
|
|
Maximum AC Input Current
|
50A
|
|
Nominal Operating Frequency
|
50/60Hz
|
|
Surge Power
|
20400W
|
|
BATTERY MODE OUTPUT (AC) |
|
Nominal Output Voltage |
220/230/240VAC |
|
Output Waveform |
Pure sine wave |
|
Efficiency (DC to AC) |
94% |
|
BATTERY & CHARGER |
|
Nominal DC Voltage |
48VDC |
|
Maximum Charging Current(Solar to AC) |
160A |
|
Maximum AC Charging Current |
160A |
|
GENERAL |
|
Communication interface |
WIFI |
|
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
|
Operating Temperature |
–10°C - 50°C |
|
Storage Temperature |
–15°C - 60°C |





1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.